The DICOM tags for the first dicom file in this scan.
Tag Description Value
(0002,0001) File Meta Information Version 00\01
(0002,0002) Media Storage SOP Class UID 1.2.840.10008.5.1.4.1.1.4
(0002,0003) Media Storage SOP Instance UID 1.3.6.1.4.1.40744.99.230931401339095828046543102894453037526
(0002,0010) Transfer Syntax UID 1.2.840.10008.1.2
(0002,0012) Implementation Class UID 1.2.40.0.13.1.1
(0002,0013) Implementation Version Name dcm4che-2.0
(0002,0016) Source Application Entity Title CTP
(0008,0005) Specific Character Set ISO_IR 100
(0008,0008) Image Type ORIGINAL\PRIMARY\OTHER
(0008,0016) SOP Class UID 1.2.840.10008.5.1.4.1.1.4
(0008,0018) SOP Instance UID 1.3.6.1.4.1.40744.99.230931401339095828046543102894453037526
(0008,0020) Study Date 20000101
(0008,0021) Series Date 20000101
(0008,0022) Acquisition Date 20000101
(0008,0023) Content Date 20000101
(0008,0030) Study Time 000000
(0008,0031) Series Time 000000
(0008,0032) Acquisition Time 000000
(0008,0033) Content Time 000000
(0008,0060) Modality MR
(0008,0070) Manufacturer GE MEDICAL SYSTEMS
(0008,0090) Referring Physician’s Name
(0008,1030) Study Description MRI BRAIN TESTSUBJECT
(0008,103E) Series Description --ANONYMIZ_00000000_0000000.00_T1final--
(0008,1090) Manufacturer’s Model Name SIGNA EXCITE
(0008,1140) Referenced Image Sequence
(0008,1140) Referenced SOP Class UID 1.2.840.10008.5.1.4.1.1.4
(0008,1140) Referenced SOP Instance UID 1.3.6.1.4.1.40744.99.212831687689160594843297115829981264291
(0008,1140) Referenced Image Sequence
(0008,1140) Referenced SOP Class UID 1.2.840.10008.5.1.4.1.1.4
(0008,1140) Referenced SOP Instance UID 1.3.6.1.4.1.40744.99.142497077878919713362908044884996844422
(0008,1140) Referenced Image Sequence
(0008,1140) Referenced SOP Class UID 1.2.840.10008.5.1.4.1.1.4
(0008,1140) Referenced SOP Instance UID 1.3.6.1.4.1.40744.99.133847575111890296325851658648721114747
(0010,0010) Patient’s Name ANONYMIZ
(0010,0020) Patient ID ANONYMIZ
(0010,0030) Patient’s Birth Date
(0018,0020) Scanning Sequence GR
(0018,0021) Sequence Variant SS\SP\SK
(0018,0022) Scan Options FAST_GEMS\VB_GEMS\EDR_GEMS\VASCTOF_GEMS\PFF
(0018,0023) MR Acquisition Type 3D
(0018,0025) Angio Flag N
(0018,0050) Slice Thickness 1.6
(0018,0080) Repetition Time 13.76
(0018,0081) Echo Time 2.752
(0018,0082) Inversion Time 400
(0018,0083) Number of Averages 1
(0018,0084) Imaging Frequency 63.848095
(0018,0085) Imaged Nucleus 1H
(0018,0086) Echo Number(s) 1
(0018,0087) Magnetic Field Strength 1.5
(0018,0088) Spacing Between Slices 0.800001
(0018,0091) Echo Train Length 0
(0018,0093) Percent Sampling 100
(0018,0094) Percent Phase Field of View 70
(0018,0095) Pixel Bandwidth 48.8281
(0018,1020) Software Version(s) 11
(0018,1088) Heart Rate 0
(0018,1090) Cardiac Number of Images 0
(0018,1094) Trigger Window 0
(0018,1100) Reconstruction Diameter 250
(0018,1250) Receive Coil Name 8HRBRAIN
(0018,1310) Acquisition Matrix 0\416\256\0
(0018,1312) In-plane Phase Encoding Direction ROW
(0018,1314) Flip Angle 20
(0018,1315) Variable Flip Angle Flag N
(0018,1316) SAR 0.135762
(0018,5100) Patient Position HFS
(0020,000D) Study Instance UID 1.3.6.1.4.1.40744.99.141253643552231291697372180164147575979
(0020,000E) Series Instance UID 1.3.6.1.4.1.40744.99.316716475474323873433568441866942931164
(0020,0010) Study ID
(0020,0011) Series Number 6
(0020,0012) Acquisition Number 1
(0020,0013) Instance Number 135
(0020,0032) Image Position (Patient) -124.756\-160.853\66.3214
(0020,0037) Image Orientation (Patient) 1\-0\0\-0\1\0
(0020,0052) Frame of Reference UID 1.3.6.1.4.1.40744.99.104635196113805318932590775450871014577
(0020,0060) Laterality
(0020,0110) Temporal Resolution 0
(0020,1040) Position Reference Indicator
(0020,1041) Slice Location 66.32136536
(0028,0002) Samples per Pixel 1
(0028,0004) Photometric Interpretation MONOCHROME2
(0028,0010) Rows 512
(0028,0011) Columns 512
(0028,0030) Pixel Spacing 0.488281\0.488281
(0028,0100) Bits Allocated 16
(0028,0101) Bits Stored 16
(0028,0102) High Bit 15
(0028,0103) Pixel Representation 1
(0028,0120) Pixel Padding Value 0
(0028,1050) Window Center 1563
(0028,1051) Window Width 3127